Emergency gas shut off valve for earthquakes in Whittier

After a quake, the gas meter valve stays on unless you smell, hear or see a leak. This page covers that rule, what an automatic seismic valve adds, and how a Whittier plumber installs one.

Last changed

Ask for a quote

Gas meter with a seismic shut-off valve fitted on the service pipe just after the meter.

SoCalGas does not tell customers to close the gas after every quake. The meter valve gets closed on a sulfur smell, a hiss or other plain evidence of a leak, and then only when reaching it is safe. Below is that rule, plus what an automatic valve adds. Wider context on pipework sits in gas line work.

Does the gas belong off after every tremor?

Only when something points to a leak: the sulfur smell added to natural gas, a hissing sound at a pipe or the meter, or damage you can see. In those cases SoCalGas wants the meter closed, provided you can reach it safely. Suspect a leak? Get the household out before anything else, then phone from a safe place.

According to SoCalGas, shaking alone does not normally rupture gas lines. Closing the valve out of habit therefore creates its own trouble: you cannot reopen it on your own, service stays off until the utility arrives, and after a large event that wait can run long.

With a suspected leak, the order is: walk out, then SoCalGas (1-800-427-2200) can be called from out front. Dial 911 as well if lives are at risk. On the way out avoid light switches, flames and the garage car, since any spark matters.

What can I do to be ready at the meter?

Store a 12-inch (or bigger) adjustable wrench by the exit or near the shutoff, not hung on the meter or the gas pipe, as SoCalGas points out. Learn where your meter is and how its valve looks: the flat tab running along the pipe means open, and turning it a quarter of a circle across the pipe closes the gas.

Run through the plan with everyone at home one time:

  • Who closes the valve, and who calls.
  • Where everyone meets outside the house.
  • That a smell of gas means leave first, ask questions later.

Each gas appliance has its own small valve, so one appliance can be stopped without closing the whole house. Some of those valves need a wrench, so find out which. A water heater whose valve was shut will turn out cold, a symptom discussed under no hot water despite the heater being on.

How does an automatic quake valve work?

A valve on the gas line, either mechanical or electronic, that snaps shut when it feels strong ground motion, so gas stops flowing even if nobody is home. Some models bolt on at the meter, others sit on the house piping. The aim is to reduce fire danger when a pipe or appliance connector fails.

Quake valve with its flap lying open so gas flows, and dropped shut after strong shaking.

Benefits and limits to know about:

  • It acts when you are not there, asleep, or hurt.
  • It works only when fitted properly and matched to the pipe and the gas load.
  • A closed valve can create a false sense that the gas is safe. A tripped valve can also mean a break somewhere in the house.
  • It needs periodic checking and cannot replace a leak check on the home's piping.

Have a plumber tell you which type suits your meter and how it is proven to work. A valve that cuts off too early is a nuisance; one that fails to close is no help.

Book a plumber quote

Fill this in and we'll arrange a local plumber specialist to come and price the job.

Lets the business see where the job is before they quote.

We earn a referral fee from the plumber who takes your job. You pay us nothing.

Can I reset an earthquake gas valve myself?

No. Per SoCalGas, only its own field staff open gas at the meter, after the piping and appliances inside have been inspected. Reopening a line that has a hidden break can fill the house with gas. A tripped valve is a warning, so have the system examined.

When a plumber handles the reset, the piping is tested, each appliance connection is checked and leaks are ruled out before gas comes back. Following a repair, a line is typically pressure tested, and air is purged out of it before pilots are relit. The sequence appears on the page about resetting a quake valve, warnings included. The same page matters if you need gas line repair or gas line installation work done first.

Who can install an earthquake shut off valve in Whittier?

Gas piping is contractor work, not a homeowner project. California's contractor license rule kicks in whenever a permit is needed, and altering gas lines generally needs one. Expect the plumber to obtain it and schedule the inspection. Whittier's office for this is Building and Safety, (562) 567-9320.

Questions to ask any plumber who offers the installation:

  1. Which valve model and what pipe size does it suit?
  2. Is a permit included in the quote, and will you schedule the inspection?
  3. What happens to my appliances after the valve is set?
  4. Who tests the line and for how long?

For code questions, see residential gas piping codes. Flexible connectors have their own rules, covered under flexible natural gas line sizing.

What should a seismic valve installation cost here?

The valve model, the meter location, the pipe size and any piping that needs fixing first all move the number, so no figure is printed here. A quote for the real job beats a guess. For general patterns in gas work pricing, read what gas line work costs.

Permit fees, the inspection and the distance from the meter also change the total. When you compare written quotes, look for the valve, the labor, the permit and the testing each listed on its own line.

How do I get a valve installed or inspected?

Say what you need in the price request form: a new valve, a look at an existing one, or a system check following a shake. A plumber travels to you in Whittier or a neighboring city, with a written estimate delivered before the job starts. Anything urgent belongs under emergency plumbing.

Helpful to mention:

  • Your address and the meter location.
  • Whether an automatic valve already exists.
  • Any gas smell, hiss or damage you noticed.
  • Which appliances run on gas.

The Rio Hondo Plumbing front page covers the other trades we handle.

Common questions

Do I close the gas valve with every shake?

No. SoCalGas asks customers to close the valve when a smell, a hiss or damage suggests a leak, and when it is safe to reach. After that it remains shut until the utility restores service, so closing it needlessly means waiting without gas.

Who turns the gas back on after I close the valve?

Staff from SoCalGas open the gas at the meter. They want the piping and appliances inside inspected first, and a plumber or heating contractor may have to repair something beforehand. Arrange it through 1-800-427-2200, and expect delays following a large event.

Does the law demand an automatic quake valve on my house?

This page does not claim any blanket requirement. Rules differ with the city and the house, so ask Whittier's Building and Safety Division at (562) 567-9320 or a plumber who pulls permits. Even where one is optional, some owners add a valve for extra safety.

Can an earthquake valve trip and not mean a leak?

Yes. A strong jolt can close one even though no pipe broke. A tripped valve can also mean real damage, though, so do not simply reopen it. Have a plumber go over the piping and the appliances, then follow the steps for restoring service.

Gas smell after the shaking stopped: now what?

Go outside right away with everyone in the household. Skip switches, indoor phones, open flames and the garage car. From a distance, SoCalGas takes calls at 1-800-427-2200, and 911 is the number to use when a person is hurt or endangered. Stay outside until someone tells you the building is clear.